H39
Parameter Displayed At
Power-up
A00 to A80 A06 RW Num PT US
H40 Drive Name Characters 1-4 -2147483648 to 2147483647 0 RW Num PT US
H41 Drive Name Characters 5-8 -2147483648 to 2147483647 0 RW Num PT US
H42 Drive Name Characters 9-12 -2147483648 to 2147483647 0 RW Num PT US
H43 Drive Name Characters 13-16 -2147483648 to 2147483647 0 RW Num PT US
H45 Action On Trip Detection 00000 to 11111 00000 RW Bin US
H46 Number Of Auto reset Attempts None (0), 1 (1), 2 (2), 3 (3), 4 (4), 5 (5), Infinite (6) None (0) RW Txt US
H47 Auto-reset Delay 1.0 to 600.0 s 1.0 s RW Num US
H50 Maximum Time In Current Limit 0 to 10000 ms
2000 ms RW Num US
H51 Floor Sensor Correction Mask
Off (0) or On (1) Off (0) RW Bit NC
H52 Velocity Threshold 3 0 to 10000 mm/s 500 mm/s RW Num US
RW Read / Write RO Read-only Bit Bit parameter Txt Text string Date Date parameter Time Time parameter
Chr
Character
parameter
Bin Binary parameter IP IP address Mac MAC address Ver Version number SMP
Slot, menu,
parameter
Num Number parameter DE Destination ND No default value RA Rating dependent NC Non-copyable PT Protected
FI Filtered US User save PS Power-down save
Parameter
Range(Ú)Default(Ö)
Type
Open-Loop RFC-A RFC-S Open-Loop RFC-A RFC-S