Safety
information
Product
information
Mechanical
installation
Electrical
installation
Getting
started
User Menu A Commissioning
Advanced
Parameters
Diagnostics Optimization CT MODBUS RTU Technical Data
Installation and System Design Guide 225
Issue Number: 1
J41 Reference Acceleration 0 to 10000 mm/s² RO Num ND NC PT
J42 Deceleration Distance 0 to 32767 mm
RO Num ND NC PT
J43 Deceleration Distance Calculated 0 to 10000 mm
RO Num ND NC PT
J44 Deceleration Distance Measured 0 to 32767 mm
RO Num ND NC PT
J45 Creep Distance Measured 0 to 32767 mm
RO Num ND NC PT
J46
Speed At Floor Sensor Correction
Active
0 to 32767 mm/s RO Num ND NC PT
J47
Remaining Floor Sensor Correction
Distance
-32768 to 32767 mm RO Num ND NC PT
J48 Velocity Threshold 1 Status Output Off (0) or On (1)
RO Bit ND NC PT
J49 Velocity Threshold 2 Status Output Off (0) or On (1)
RO Bit ND NC PT
J50 Final Speed Reference
±VM_SPEED RO Num ND NC PT FI
J51 Speed Feedback
±VM_SPEED RO Num ND NC PT FI
J52 Drive Encoder Revolutions
0 to 65535 RO Num ND NC PT PS
J53 Drive Encoder Position
0 to 65535 RO Num ND NC PT PS
J54 Drive Encoder Fine Position
0 to 65535 RO Num ND NC PT
J55 Sensorless Mode Position
-2147483648 to
2147483647
RO Num ND NC PT
J56 Maximum Distance Error
0 to 10000 mm RO Num ND NC PT
J57 Maximum Speed Error
0 to 10000 mm/s RO Num ND NC PT
J58 Travel Counter -2147483648 to 2147483647
RW Num ND NC PT PS
J59 Output Power ±VM_POWER kW
RO Num ND NC PT FI
J60 Output Frequency
±VM_SPEED_
FREQ_REF Hz
±2000.0 Hz
RO Num ND NC PT FI
J61 Output Voltage ±VM_AC_VOLTAGE V
RO Num ND NC PT FI
J62 Last Travel Maximum Power 0.000 to 2147483.647 kW
RO Num ND NC PT
J63 Last Travel Maximum Motor Voltage 0 to 32767 V
RO Num ND NC PT
J64 Last Travel Maximum Current 0.000 to 2147483.647 A
RO Num ND NC PT
J65 D.C. Bus Voltage ±VM_DC_VOLTAGE V
RO Num ND NC PT FI
J66 Internal IO Identifier 0 to 255
RO Num ND NC PT
J67 Encoder Feedback Interface Identifier 0 to 255
RO Num ND NC PT
J68 Menu Access Status Menu 0 (0), All Menus (1)
RO Txt ND NC PT PS
J69 Enable Conditions 000000000000 to 111111111111
RO Bin ND NC PT
J70 Drive Event Flags 00 to 11 00 RW Bin NC
J71 Monitored Temperature 1 ±250 °C
RO Num ND NC PT
J72 Monitored Temperature 2 ±250 °C
RO Num ND NC PT
J73 Monitored Temperature 3 ±250 °C
RO Num ND NC PT
J74 Monitor Temperature Select 1 0 to 1999 1001 RW Num US
J75 Monitor Temperature Select2 0 to 1999 1002 RW Num US
J76 Monitor Temperature Select 3 0 to 1999 1 RW Num US
J77 Inverter Temperature ±250 °C
RO Num ND NC PT
J78
Percentage Of DC Link Thermal Trip
Level
0 to 100 %
RO Num ND NC PT
J79
Percentage Of Drive Thermal Trip
Level
0 to 100 %
RO Num ND NC PT
J80 Date 00-00-00 to 31-12-99
RW Date ND NC PT
J81 Time 00:00:00 to 23:59:59
RW Time ND NC PT
J82 Day Of Week
Sunday (0), Monday (1), Tuesday (2),
Wednesday (3), Thursday (4), Friday (5),
Saturday (6)
RO Txt ND NC PT
J83 Date And Time Offset ±24.00 Hours 0.00 Hours RW Num US
J84 Energy Meter: MWh ±999.9 MWh
RO Num ND NC PT PS
J85 Energy Meter: kWh ±99.99 kWh
RO Num ND NC PT PS
J86 Energy Cost Per kWh 0.0 to 600.0 0.0 RW Num US
J87 Running Cost kWh ±32000
RO Num ND NC PT
J88 Drive Date Code 0 to 65535
RO Num ND NC PT
J89 Serial Number LS 000000000 to 999999999
RO Num ND NC PT
J90 Serial Number MS 0 to 999999999
RO Num ND NC PT
J91 Drive Identifier Characters 1160982576 to 2147483647
RO Num ND NC PT
J92
Drive Identifier Rating And
Configuration
00000000 to 99999999
RO Num ND NC PT
J93 Extra Identifier Characters 1 -2147483648 to 2147483647
RO Num ND NC PT
J94 Extra Identifier Characters 2 -2147483648 to 2147483647
RO Num ND NC PT
Parameter
Range(Ú) Default(Ö)
Type
Open-Loop RFC-A RFC-S Open-Loop RFC-A RFC-S