EasyManua.ls Logo

Nidec MCE Motion 4000 - LS-EDGE Steel Tape; Parameter Settings; Hoistway Learn, LS-EDGE; Slowdown Learn, ETS Placement

Nidec MCE Motion 4000
416 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Learning Floor Levels & Counterweight Position
42-02-2M01 A1 3-5
3
Motion 4000
LS-EDGE Steel Tape
Parameter Settings
1. Verify F7, parameter 191 is set to LS-EDGE.
2. Verify F7, 149 is set to the correct Contract Speed.
Hoistway Learn, LS-EDGE
1. Place the car on Inspection operation.
2. Move the car to the bottom terminal.
3. Set the F6 function switch in the UP/ON position.
4. The LCD will display HOISTWAY LEARN, PRESS S.
5. Press S to initiate learn.
6. Place car on TEST mode. Shut off INSPECTION. Follow instructions on the LCD.
Synopsis As you follow the instructions on the LCD, the car will first travel down to the
bottom terminal then move up to locate the center of the door zone magnet. From the bottom
terminal, the car will move up the hoistway finding each door zone and indicating the height in
inches of each door zone magnet center (Front and/or Rear as appropriate). Upon reaching the
top terminal, the LCD will report hoistway information stored and offer the option to press N if
you are Done or S if you want to restart the learn operation.
7. Press N when hoistway learn reports complete to exit the operation.
8. Place F6 in the Down position.
Once the door zones have been learned, you are ready to learn terminal and emergency slow-
down positions, Slowdown Learn, ETS Placement on page 3-5.
Offset Motion 4000 allow the door zone heights to be individually adjusted in 0.10 inch
increments to compensate for minor floor height errors up to a maximum +/- 0.9 inches for
LS-EDGE.
Slowdown Learn, ETS Placement
This operation determines locations for slowdown and emergency switches for the job and, if
ETS magnets are used, automatically assists you in placing them.
1. Please refer to “Terminal Switch Options, 69 - 74” on page 4-126.
2. Reference your job prints and activate the switches uses on your job.
3. Move the car to the bottom terminal on Test mode.
4. Set the F5 function switch in the UP/ON position.
5. Move to the Terminal Limit Utilities menu and press S to select.
6. The LCD will display PERFORM UXTS AND DXTS LEARN. Press S to Select.
7. The LCD will display TERMINAL LEARN/S: START. Press S to begin.
8. The LCD will ask you to enter switch tripping thresholds for the ETS switches (if used),
then for the NTS switches used on the job.
Press S to move the cursor to a digit position.
Use +/- buttons to increment/decrement values.
Typical ETS setting is 80% (of contract speed). Press N to move on.
NTS settings depend on switch position:
•Outermost NTS: 90% (of contract speed). Press N to move to next NTS switch.

Table of Contents