NE200/300 Series Drive User Manual
Chapter 6 Parameter description 157
13 Pulse input 0.150.0KHz
14
Communication
setup
See Communication
appendix
15 Reserved ---
16 Output current 0~2 time rated current
F7.22
AO output range
selection
Range: 010
F7.22
AO1 output range
selection
Range: 010
F7.23
Reserved ---
F7.23
AO2 output range
selection
Range: 010
0: 010V / 020mA
1: 210V / 420mA
F7.24
Gain of AO Range: 1200%100%
F7.24
Gain of AO1 Range: 1200%100%
F7.25
Reserved ---
F7.25
Gain of AO2 Range: 1~200%100%
The drive output and users instrument systems are likely to produce
error; you can adjust the output gain (AO1) for the meter calibration and the
change of measuring range.
F7.26
Y1 Maximum output
pulse freq.
Range: Y1 Minimum output pulse
freq.~50.00kHz10.00kHz
F7.26
DO Max. output pulse
freq.
Range: DO Minimum output pulse
freq.~50Hz10.00kHz
F7.27
Y1 Minimum output pulse
freq.
Range: 0.00Y1 Maximum
output pulse frequency0.00kH
F7.27
DO Min. output pulse
freq.
Range: 0.00DO Max. output
pulse freq.0.00kH