NE200/300 Series Drive User Manual
Chapter 6 Parameter description 185
FP.02 Parameter initialization Range: 0~20
0: No operation
1: Clear fault history
When FP.02 is set to 1, the fault records of FF.00~FF.07 will be
cleared.
2: Restore to default setting
When FP.02 is set to 2, the parameters (except running history and
user password) are restored to defaults.
FP.03 Parameter copy Range: 0~20
0: No action
1: Parameters download
According to the type parameter of the keypad preservation (whether
has motor parameters, etc), automatically download to the control
board
2: Parameters upload (except motors parameters)
All parameters will upload to EEPROM of keypad except “Running
history record” (Group FF) and “motor parameters” (Group F5).
3: Parameters upload (all parameters)
All parameters will upload to the EEPROM of keypad except “Running
history record” (Group FF).
FP.04 Parameter upload protection Range: 010
0: Protection enabled
When the keypad has stored effective parameters, uploading
parameters to keypad is invalid and report “copy fault”
1: Protection disabled
No matter the panel has stored effective parameters or not, the
uploading operation will upload the present parameters from the
control board to the keypad panel.

Table of Contents