EasyManua.ls Logo

Nidec NE200-2S0007GB - Group F3: Vector Control Parameters

Nidec NE200-2S0007GB
244 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NE200/300 Series Drive User Manual
64 Chapter 5 List of Parameters
Code
Description Setting range Default Modify
M
odbus
Address
F3.00
Speed loop
proportional gain 1
1~3000 1000 0400H
F3.01
Speed loop integral
time 1
1~3000
300 0401H
F3.02
Switching
frequency 1
0.0
60.00Hz 5.00Hz 0402H
F3.03
Speed loop
proportional gain 2
1~3000 800 0403H
F3.04
Speed loop integral
time 2
1~3000 200 0404H
F3.05
Switching
frequency 2
0.0
60.00Hz 10.00Hz 0405H
F3.06
Speed loop filter
time constant
0
500ms
2ms
3ms
0406H
F3.07
Current loop
proportional
coefficient
0
6000 3000 0407H
F3.08
Current loop
integral coefficient
0
6000 1500 0408H
F3.09
VC Slip
compensation
0.0
200.0% 100.00% 0409H
F3.10
Torque control
0:Torque control
Disabled
0 040AH
1:Torque digital
setting(F3.11)
2:AI1 3:AI2
4:Reserved
5:communication
6:keypad
potentiometer
Torque control
0:Torque control
Disabled
1:Torque digital
setting(F3.11)
2:AI1 3:AI2
0 040AH

Table of Contents

Other manuals for Nidec NE200-2S0007GB

Related product manuals