NE200/300 Series Drive User Manual
68 Chapter 5 List of Parameters
Code
Description
Setting range Default
Modify
Modbus
Address
F4.00
V/F curve
setting
0: Constant torque load
V/F
0 × 0500H
1: 2.0 power decreasing
torque
2: 1.5 power decreasing
torque
3: 1.2 power decreasing
torque
4: Multiple dots V/F
F4.01
V/F freq. F1 0.0
F4.03 10.00Hz
× 0501H
F4.02
V/F voltage
V1
0.0
100.0% 20.00%
× 0502H
F4.03
V/F freq. F2 F4.01
F4.05 25.00Hz
× 0503H
F4.04
V/F voltage
V2
0.0
100.0% 50.00%
× 0504H
F4.05
V/F freq. F3 F4.03
F0.10 40.00Hz
× 0505H
F4.06
V/F voltage
V3
0
100.0% 80.00%
× 0506H
F4.07
Torque boost
0.0%: Auto boost
0.00%
0507H
0.1
30.0%: Manual
boost
F4.08
Manual
torque boost
cutoff point
0.00
60.00Hz 50.00Hz
0508H
F4.09
Slip
compensation
coefficient
0.0
200.0% 0.00% 0509H
F4.10
Slip
compensation
filtering time
0.01
2.55s 0.20s 050AH