EasyManua.ls Logo

Nidec NE200-2S0015GB - F6 Input terminals group

Nidec NE200-2S0015GB
244 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NE200/300 Series Drive User Manual
Chapter 5 List of Parameters 79
Code
Description Setting range Default
Modify
Modbus
Address
F7.05
Freq. arrival
(FAR) detection
width
0.00
10.00Hz 2.50Hz 0805H
F7.06
Frequency
detection value
1 (FDT1 level)
0.00
600.0Hz 5.00Hz 0806H
F7.07
Freq. detection
lag1 (FDT1-lag)
0.00
10.00Hz 1.00Hz 0807H
F7.08
Frequency
detection value
2 (FDT2 level)
0.00
320.0Hz 5Hz 0808H
Frequency
detection value
2 (FDT2 level)
0.00
320.0Hz 25.00Hz
0808H
F7.09
Freq. detection
lag2 (FDT2-lag)
0.00
10.00Hz 1.00Hz 0809H
F7.10
Up detection
frequency
0.00
550.0Hz 50.00Hz
080AH
F7.11
Down detection
frequency
0.00
550.0Hz 0.00Hz 080BH
F7.12
Torque
detection
reference
0.0
200.0% 100.00%
080CH
F7.13
Preset Counting
arrival value
0
9999 0 080DH
F7.14
Preset Timing
arrival value
0.0
6553.0s 0.0s 080EH
F7.16
AI1 compare
threshold 1
0.00
10.00v 0.00v 0810H
F7.17
AI1 compare
threshold 2
0.00
10.00v 0.00v 0811H
F7.18
Analog compare
hysteresis error
0.00
30.00v 0.20v 0812H

Table of Contents

Other manuals for Nidec NE200-2S0015GB

Related product manuals