NE200&300 Quick Start Guide
33
Code
Description Setting range Default Modify
M
odbus
Address
speed limit setting(F3.13)
1: AI1 2: AI2
3: PULSE 4:
communication
5: keypad
potentiometer
F3.13
Torque control
speed limit digital
setting
0.00
550.0Hz 50.00Hz 040DH
F3.14
Encoder pulse
number
1~9999 1000 040EH
F3.15
Motor and PG
reduction ratio
0.010~50.000 1.000 040FH
F3.16
PG direction
0: Forward 1:
Reverse
0 0410H
F3.17
ACC/DEC limit
controlled by PG
0: Limited 1: No
limited
0 0411H
F3.18
SVC speed
calculation filter
0~15 5 0412H
F3.19
SVC mode
0: Mode1
0
0413H
1: Mode2
F3.20
SVC mode2 flux
weaken coefficient
20~500% 100% 0414H
F3.21
Flux weaken
control selection
0: Disable 1:
Enable
0 0415H
F3.22
Torque limit
compensation
coefficient while
constant power
output
60.0
300.0%
85%
200%
0416H
F3.23
Reserved Reserved Reserved
Reserve
d
F3.24
Torque ref. terminal
single modulation
0.0~10% 0.00% 0418H
F3.25
Torque ref. terminal
0.0~100% 50% 0419H