NE200&300 Quick Start Guide
46
Code
Description Setting range Default
Modify
Modbus
Address
17: Under voltage
status output
18: Drive overload
pre-warning
19: Fixed-length
arrived, level signal
20: PID in dormancy
21: AI1>AI2
22: AI1<F7.16
23: AI1>F7.16
24:
F7.16<AI1<F7.17
25: Frequency lower
limit arrival
26: Multi-pumps
system auxiliary
pump control signal
27: Communication
setting
28: Drive running
time arrival
29: Running in FWD
30: Running in REV
31: Instantaneous
power loss
processing
F7.05
Freq. arrival
(FAR) detection
width
0.00
10.00Hz 2.50Hz 0805H
F7.06
Frequency
detection value
1 (FDT1 level)
0.00
600.0Hz 5.00Hz 0806H
F7.07
Freq. detection
lag1 (FDT1-lag)
0.00
10.00Hz 1.00Hz 0807H
F7.08
Frequency
detection value
2 (FDT2 level)
0.00
320.0Hz 5Hz 0808H