NE200/300 Series Drive User Manual
182 Chapter 6 Parameter description
FE.22 External counting value (no unit)
Range: 0~3【0】
These parameters define the display in stop and running monitoring
condition.
0: No display
1: Display only in stop process
2: Display only during running
3: Display in stop and running
Explanation:
In stop process monitoring, if no parameter is set to show in monitor
state, reference frequency will be displayed. In running monitoring
state, if no parameter is set to be displayed, the output frequency
(before compensation) will be displayed.
The indication for analog PID reference and analog PID feedback is
“Hz” +” A”,
For PID reference, the Hz+A is blinking; while for PID feedback, the
Hz+A is constant ON.
The terminal status is shown by four digits of LED without unit
indicator, the specific meaning shown in figure 6-28.
Fig 6-28 Terminal status diagram
6.16 Running history record group (FF)
FF.00 Type of latest fault Setting range: 0~27【NULL】
FF.01 Output freq. at latest fault Setting range: 0~Frequency