SI-Ethernet User Guide 37
Issue: 3
Safety
information
Introduction
Mechanical
installation
Electrical
installation
Getting started
Parameters
Key features
and Protocols
PC Tools
Applications
Security Diagnostics
Glossary of
terms
Index
The hardware version of the option module is in the format of xx.yy.
The module serial number is available as a pair of 32-bit values where Serial Number LS
(S.00.004) provides the least significant 8 decimal digits, and Serial Number MS (S.00.005)
provides the most significant 8 decimal digits. The reconstructed serial number is ((S.00.005 x
100000000) + S.00.004). For example serial number "0001234567898765" would be stored as
S.00.005 = 12345 and S.00.004 = 67898765.
See Serial Number LS (S.00.004)
This parameter displays the current status of the module. All possible values are shown in the table
overleaf.
S.00.003 Hardware Version
Minimum 00.00 Maximum 99.99
Default None Units None
Type 16 Bit Volatile Update Rate Written on module
initialization
Display Format None Decimal Places 2
Coding RO, ND, NC, PT
S.00.004 Serial Number LS
Minimum 0 Maximum 99999999
Default None Units None
Type 32 Bit Volatile Update Rate Power-up write
Display Format Lead Zero Pad Decimal Places 0
Coding RO, ND, NC, PT
S.00.005 Serial Number MS
Minimum 0 Maximum 99999999
Default None Units None
Type 32 Bit Volatile Update Rate Power-up write
Display Format None Decimal Places 0
Coding RO, ND, NC, PT
S.00.006 Status
Minimum
-2
(Display: Bootldr -
Update)
Maximum
3
(Display: Error)
Default None Units None
Type 8 Bit Volatile Update Rate Background
Display Format Text Decimal Places 0
Coding RO, Txt, ND, NC, PT