Defines the event to trigger in the given destination, as specified in Rx3 Timeout Event Destination
(S.10.067), if a cyclic data timeout occurs on the Rx3 link.
S.10.068 Rx3 Timeout Event Type
Minimum
0
(Display: No Event)
Maximum
4
(Display: Event3)
Default
0
(Display: No Event)
Units None
Type 8 Bit User save Update Rate Read on reset
Display Format None Decimal Places 0
Coding RW, Txt, BU
Value Text Description
0 No Event No event
1 Event Trigger module event
2 Event 1 Trigger module event 1
3 Event 2 Trigger module event 2
4 Event 3 Trigger module event 3
This feature is not yet implemented.
S.10.069 Rx3 Link Status
Minimum
-31
(Display: Disabled)
Maximum
2
(Display: OK sync)
Default None Units None
Type 8 Bit Volatile Update Rate Write on reset
Display Format None Decimal Places 0
Coding RO, Txt, NC, ND, PT
Value Text Description
-31 Disabled Easy Mode protocol is disabled or link number set to 0
-30 VLAN disabled
VLAN is required in order to guarantee timing in
synchronous mode but it is disabled
-29 Reserved 29 Reserved for future use
-28 Reserved 28 Reserved for future use
-27 Reserved 27 Reserved for future use
-26 Reserved 26 Reserved for future use
-25 Reserved 25 Reserved for future use
-24 Reserved 24 Reserved for future use
-23 Reserved 23 Reserved for future use
-22 Invalid DST IP Destination IP address is invalid