EasyManua.ls Logo

Nikon VAA35001 Coolpix S1 - Lens Adjustment

Nikon VAA35001 Coolpix S1
83 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VAA35001-R.3666.A
- A22 S1 -
+36 +250
040915
0001
A1
Input the value.
[How to adjust]
Turn on the camera.
Connect the USB cable to PC.
Double-click on "DscCa1Di.exe".
Select "Lens Data” on "Test" of "LCD".
Input the value of the bar code, which is attached on the rear of the lens, into the text box of Lens data Dialog.
Then, click "Set".
Click Exit and close the dialog box.
11. Lens adjustment
[Preparations]
Turn on the collimator (J63090). (Do not connect the USB cable to PC yet.)
Turn on the camera.
Check the positions so that the chart center in the collimator should be at the center of the screen.
Turn off the camera once.
[Conditions]
Set the collimator and camera (i.e. the front surface of lens) as near as possible between them (approx.5.5 cm).
When the camera is mounted on the cradle, the camera must be right in front of the collimator.
Place the cradle in a horizontal position as much as possible. (Fig. 1)
Fig.1
Set it horizontally.
Adjustment collimator
Camera
ref. Page A1.




