Instruction manual
For
Model PS30SW
DC Switching Power Supply
Question and Answer IconNeed help?

Do you have a question about the Nissei PS30SW II and is the answer not in the manual?

Nissei PS30SW II Specifications

General IconGeneral
ModelPS30SW II
ManufacturerNissei
CategoryPower Supply
Output Voltage0-30V
Output Current0-3A
Output Power90W
Voltage Regulation≤ 0.01% + 3mV
Ripple and Noise≤ 1mVrms
Display TypeLED
Voltage Resolution10mV
Current Resolution1mA
Weight3.5 kg
Cooling MethodFan
Operating Temperature0°C to 40°C
Protection FeaturesOverload, Short Circuit, Over Temperature

Summary

Product Introduction

Front Panel Overview

Power ON/OFF

Main switch to turn the power supply on or off.

Display Indicator

LED indicator that shows output status.

Meter Display Switch

Selects between voltage (V) and current (A) display.

Voltage Adjust

Variable control for output voltage between 9-15V.

Cigarette Plug Output

Output terminal suitable for currents up to 10A.

Second Output Terminal

Additional output terminal for currents up to 3A.

Rear Panel Features

Main Output Terminals

Connectors for output, red for positive (+), black for negative (-).

Fixed/Variable Voltage Selection

Switch to select fixed 13.8V or variable 9-15V output.

Cooling Fan

Internal fan for heat dissipation during operation.

Fuse Holder

Houses the main fuse for protection; use F5A250V for replacement.

Specifications

Usage Guidelines and Precautions

Environmental and Ventilation Requirements

Operate in a dry, ventilated area; keep fan clear (30cm).

Connection Safety

Turn off power before hookup; check polarity and tighten terminals.

Load Limits for Outputs

Respect load limits: 10A for cigarette plug, 3A for testing terminal.

Direct Connection Warnings

Avoid direct connection to batteries or low resistance loads.

Protection and Reset Procedures

Cut power on overload/short-circuit, analyze, and reset when clear.

Fuse Replacement and Chassis Safety

Use specified fuse; do not open chassis due to high voltage.

Professional Repair

Consult professionals for any malfunctions.