TDM Commands (Applicable to 7210 SAS-M when using the CES MDA)
Page 214 7210 SAS M, T, X, R6, R12, Mxp, S, Sx Interface Configuration Guide
Default flags (0x7E)
no flags (ATM)
Parameters flags — Specifies that 0x7E is used as the idle cycle flag.
ones — Specifies that 0xFF is used as the idle cycle flag.
idle-payload-fill
Syntax idle-payload-fill {all-ones | pattern pattern}
Context config>port>tdm>ds1>channel-group
config>port>tdm>e1>channel-group
Description Platforms Supported: 7210 SAS-M.
This command defines the data pattern to be transmitted when the circuit emulation service is not
operational or temporarily experiences under-run conditions.This command is only valid for cesopsn
services.
Note: See the 7210 SAS-M Services guide for more information on CESoPSN services.
Default all-ones
Parameters all-ones — Defines the 8 bit value to be transmitted as 11111111.
pattern — Transmits a user-defined pattern.
Values 0 to 255 (can be entered in decimal, binary, or hexadecimal format)
idle-signal-fill
Syntax idle-signal-fill {all-ones | pattern pattern}
no idle-signal-fill
Context config>port>tdm>ds1>channel-group
config>port>tdm>e1>channel-group
Description Platforms Supported: 7210 SAS-M.
This command defines the signaling pattern to be transmitted (4-bit value) when the circuit emulation
service is not operational or temporarily experiences underrun conditions. This command is only valid for
CES with CAS.
Note: See the 7210 SAS-M Services guide for more information on CESoPSN
Default all-ones
Parameters all-ones — Defines the 4 bit value to be transmitted as 1111.
pattern — Transmits a user-defined pattern.