Basic System Configuration Guide System Management
Edition: 01 3HE 11010 AAAC TQZZA 235
clock identity
distance (number of boundary clocks)
If the profile setting for the clock is itu-telecom-freq (ITU-T G.8265.1 profile), the
precedence order for the best master selection algorithm is as follows:
clock class
•peer ID
If the profile setting for the clock is g8275dot1-2014, the precedence order for the
best master selection algorithm is as follows if the grand master clock is connected
to a primary reference time clock (PRTC) in locked mode:
clock class
clock accuracy
PTP variance (offsetScaledLogVariance)
priority2 (user-configurable on the master clock side)
•localPriority
steps removed from the grand master
port identities
port numbers
If the profile setting for the clock is g8275dot1-2014, the precedence order for the
best master selection algorithm is as follows if the grand master clock is in holdover
and out of holdover specification, or is without a time reference since startup:
clock class
clock accuracy
PTP variance (offsetScaledLogVariance)
priority2 (user-configurable on the master clock side)
•localPriority
clock identity
steps removed from the grand master
port identities
port numbers
Figure 14 shows an example of the messaging sequence between the PTP slave
clock and the two PTP master clocks.