CONFIDENTIAL
12 (17)
RAE-3 Repairhints
Customer Care Europe & Africa Version 2.0 Approved
SCCE Training Group 13.03.2002
© 2002 Nokia Mobile Phones
Checked by:
Customer Care Training Group
Approved by:
SCCE
- Check Vmod (VTX) = 2.8V at R700. If not ok, check N100 CCONT.
- Check TXC (TX active) at power level 5 (picture 1) and at power level base (picture 2) at R792. If not ok, check N200 COBBA.
- Check SCLK at J501, SDATA at J500 and SENA at J502. (See picture below)
- If one or all three signals are not ok, probably the D300 MADLINDA is faulty.
SCLK
SDATA
SENA