EasyManua.ls Logo

Nokia Alcatel-Lucent OmniSwitch OS6360-P24X - Monitoring Chassis Components; Viewing Chassis Slot Information; Monitoring Chassis Temperature

Nokia Alcatel-Lucent OmniSwitch OS6360-P24X
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chassis and Power Supplies Monitoring Chassis Components
OmniSwitch 6360 Hardware Users Guide April 2021 page 3-31
Monitoring Chassis Components
Viewing Chassis Slot Information
To view basic slot information, enter the show module command at the CLI prompt:
-> show module
To view more detailed information, use the show module long command:
-> show module long
Monitoring Chassis Temperature
The operating temperature of your switch is a critical factor in its overall operability. In order to avoid a
temperature-related system failure, your switch must always run at a temperature within the specified
operating temperature range.
To avoid chassis over-temperature conditions, follow the important chassis airflow recommendations on
page 3-22.
To check the switch’s current temperature status, use the show temperature command. For example:
-> show temperature
Chassis/Device | Current | Range | Danger | Thresh | Status
---------------+---------+---------+--------+--------+-----------------
1/CMMA 54 15-93 93 96 UNDER THRESHOLD
1/Slot1 54 15-93 93 101 UNDER THRESHOLD
2/CMMA 39 15-85 85 88 UNDER THRESHOLD
2/Slot1 39 15-85 85 101 UNDER THRESHOLD
For more information about this command, see the “Chassis Management and Monitoring Commands”
chapter in the OmniSwitch CLI Reference Guide.