6 Parameters
BU 0210 en-3117 67
P546 Function Bus setpoint S P
Arrays
[-01] … [-03]
Scope of Application
Description
In this parameter, during bus actuation a function is allocated to the setpoint provided.
Setting values
Value Meaning
Pos: 27 2 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par amet er/ Par amet erau fli st ung (P 000 .. .)/P OS ICON/ S afet y/P 500 bis P59 9 (P OSI CON/ sa fet y)/P 546 - F kt . Bus -Soll w ert_ Eins tell wer te_ 01 @ 1 4\mod_1479723911445_388.docx @ 2305749 @ @ 1
0
Off
The bus setpoint is not used.
20
BusIO Out Bits 0-7
BusIO Out Bits 0-7 of the frequency inverter
21 Set position Low word
Lower 16-bit value of the set position (absolute position) of the
frequency inverter
22
Setpoint pos. High word
Upper 16-bit value of the set position (absolute position) of the
frequency inverter
23
Setpoint pos. Inc.Low word
Lower 16-bit value of the set position (relative position) of the
frequency inverter
24 Setpoint pos. inc. High word
Upper 16-bit value of the set position (relative position) of the
frequency inverter
25
Gear ratio factor
Setting of the speed ratio between the master and the slave
Pos: 27 6 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par amet er/ Par amet erau fli st ung (P 000 .. .)/P OS ICON/ S afet y/P 500 bis P59 9 (P OSI CON/ sa fet y)/P 552 - CAN Mas ter Zy klus @ 14\mod_1479725831915_388.docx @ 2305924 @ @ 1
P552 CAN master cycle S
Setting range
0 … 100
Arrays
[-01] =
CAN master function, cycle time system bus master function
[-02] = CANopen abs. encoder, cycle time CANopen absolute encoder
Factory setting
{ 0 }
Description
Setting of the cycle time in the cycle time system bus master mode or to CANopen
absolute encoders
Note
With setting "0" a default value is used, which depends on the selected baud rate
(P514). For details see Section 4.2.2.1 "Supplementary settings CANopen
absolute encoders"