2.6.6.1 Control connection details
Meaning, Functions
Description / Technical data
Contact
Parameter
(designation)
Meaning
No.
Function of factory setting
Digital outputs
Signalling of the operating statuses of the FI
According to EN 61131-2
24 V DC
With inductive loads: Provide protection
via free-wheeling diode!
Maximum load 20 mA
DOUT1
Digital output 1
P434 [-01]
No function
DOUT2
Digital output 2
P434 [-02]
No function
Information regarding bus control:
Digital outputs can be set with the user bits in the control word.
DOUT1: P480 [-11] = Bit8 bus controlword, setting 83/84
DOUT2: P480 [-12] = Bit9 bus controlword, setting 83/84
With P420, the digital outputs can be directly linked to a digital input P420 [-01 … -04], setting value 83/84.
P420 and P480 have priority over P343.
Digital inputs
Actuation of device using an external controller, switch or similar.
DIN1-4 according to EN 61131-2, type 1
low: 0-5 V (~ 9.5 kΩ)
high: 14-30 V (~ 2.5 - 3.5 kΩ)
Scan time: 1 ms
Response time: 3 ms
DIN1
Digital input 1, see P420 [-01]
DIN2
Digital input 2, see P420 [-02]
DIN3
Digital input 3, see P420 [-03]
DIN4
Digital input 4, see P420 [-04]
Control voltage
connection
Supply voltage for the device
24 V DC ± 25%
300 mA … 600 mA, depending on the
load on inputs and outputs and use of
options
24 V Input voltage - -
GND / 0V
Reference potential GND
-
-
Brake control
(only for Size 2 and
higher)
Connection and control of an electromechanical brake. The device generated an
output voltage. It depends on the mains voltage. The assignment of the correct
brake coil voltage must be considered in the selection.
Connected loads:
( Section 2.6.5.4 "Electromechanical
brake (optionally with size 2 and above))")
Current: ≤ 500 mA
Permissible cycle time:
up to 150 Nm ≤ 1/s
up to 250 Nm ≤ 0.5/s
MB+
Brake control
P107/114
0 / 0
MB-
Brake control

Table of Contents