NORDAC ON / ON+ (SK 3xxP) – Manual with installation instructions
66 BU 0800 en-4521
2 0.09 kW 230 V 56LP/4 10 0.18 kW 230 V 63LP/4 18 0.37 kW 230 V 71LP/4
5 0.12 PS 460 V 56LP/4 13 0.24 PS 460 V 63LP/4 21 0.50 PS 460 V 71LP/4
6 0.12 kW 230 V 63SP/4 14 0.25 kW 230 V 71SP/4 22 0.55 kW 230 V 80SP/4
9 0.16 PS 460 V 63SP/4 17 0.33 PS 460 V 71SP/4 25 0.75 PS 460 V 80SP/4
26 0.75 kW 230 V 80LP/4 36 1.50 kW 400 V 90LP/4 46 4.00 kW 400 V 112MP/4
27 1.00 PS 230 V 80LP/4 37 2.00 PS 460 V 90LP/4 47 5.00 PS 460 V 112MP/4
30 1.10 kW 230 V 90SP/4 40 2.20 kW 400 V 100LP/4 50 7.5 kW 230V 132MP
31 1.50 PS 230 V 90SP/4 41 3.00 PS 460 V 100LP/4 51 10.0 PS 230 V 132MP
34 1.50 kW 230 V 90LP/4 44 4.00 kW 230 V 112SP/4 54 1.10 kW 230 V 80T1/4
35 2.00 PS 230 V 90LP/4 45 5.00 PS 230 V 112SP/4 55 1.10 kW 400 V 80T1/4
56 1.50 kW 230 V 90T3/4 66 3.00 kW 400 V 100T2/4 76 0.35 kW 400 V 71N1/8
59 1.50 kW 400 V 80T1/4 69 4.00 kW 400 V 100T5/4 79 1.10 kW 400 V 90N1/8
60 2.20 kW 230 V 100T2/4 70 4.00 kW 400 V 100T2/4 80 1.50 kW 400 V 90N2/8
63 2.20 kW 400 V 90T1/4 73 Reserved 83 2.20 kW 400 V 90F3/8
64 3.00 kW 230 V 100T5/4 74 Reserved 84 3.00 kW 400 V 90F4/8
86 Reserved 96 1.50 kW 230 V 90F2/8
89 Reserved 99 Reserved
93 0.55 kW 230 V 71N2/8
P201 Nominal frequency S P
The default setting depends on the nominal power of the FI.
The nominal motor frequency determines the V/f break point at which the FI supplies
the nominal voltage (P204) at the output.
P202 Nominal speed S P
The default setting depends on the nominal power of the FI.
The nominal motor speed is important for correct calculation and control of the motor
slip and the speed display (P001 = 1).
P203 Nominal current S P
The default setting depends on the nominal power of the FI.
The nominal motor current is a decisive parameter for current vector control.