5 Parameter
BU 0800 en-4521 81
P336 Mode rotorpos ident S
{ 0 }
"Mode rotorpos ident" The precise position of the rotor must be known in order to
operate a PMSM. This can be determined by various methods.
Use of the parameter is only advisable if the test signal method is set (P330).
Value Meaning
0 First enable
Identification of the PMSM rotor position is performed when the
drive is enabled for the first time.
Identification of the PMSM rotor position is performed when the
supply voltage is applied for the first time.
2 Digital input/Bus input Bit
Identification of the PMSM rotor position is triggered with an external
order by means of a binary bit (digital input P420 or Bus-in bit P480,
setting {79}, "rotor position identification"). Identification of the rotor
position is only performed if the FI is in the “ready for switch-on” state
and the rotor position is not known (see
,
setting {28}).
3 Each enable
Identification of the PMSM rotor position is performed on each enable.
P350 PLC functionality
Activation of the integrated PLC
Value Meaning
The PLC is not active, control of the FI is via IOs.
The PLC is active, control of the FI is via the PLC depending on