Functional Safety – Supplementary manual for series SK 500P
52 BU 0630 en-2020
Average input current For SK 510P, SK 540P:
Input voltage VIS_24V (91):
Average input current For SK CU5-STO, SK CU5-MLT:
Input voltage VIS1_24V (91):
Input voltage VIS2_24V (92):
Increased current on switch-on or after a test pulse from an OSSD
Due to the support capacitors of the safe shut-
down method, there is an increased current
consumption on switch-on and after a test pulse from an OSSD. The Safe Pulse Block is equipped
with an active current limiter in order to reduce the load on safety outputs to a minimum.
Pos: 32 1 /Allg emein/ Allg emeing ültig e Mod ule/---------Sei tenum bruc h k omp akt --------- @ 13\mod_1476369695906_0.docx @ 2265495 @ @ 1