Functional Safety – Supplementary manual for series SK 500P
48 BU 0630 en-2020
6 Operating status messages
The majority of functions and operating data of the frequency inverter are continuously monitored and
simultaneously compared with limit values. If a deviation is detected, the frequency inverter responds
with a warning or an error message.
For basic information about this, please refer to the frequency inverter operating instructions.
All errors or reasons which result in a switch-on block of the frequency inverter and which are
associated with STO functionality are listed below.
Pos: 29 1 /Anlei tung en/El ektr onik/FU und Star ter/6 . Meld ungen zum B etrie bsz ust and /Stör m eld ung en (T abel len über sc hrif t) @ 3\m od_1361803456862_388.docx @ 59874 @ 5 @ 1
Error messages
Display in the
SimpleBox / ControlBox
Fault
Text in the ParameterBox
Cause
• Remedy
Group Details in P700
[-01] / P701
Pos: 292 /Anl eit ung en/El ektr oni k/F U und Star ter /6. M el dung en zum Betr ie bsz usta nd/ Stör mel dung en (A ufli stung )/F ehl er E 004 [ BU 06 30] @ 44\m od_1593162083709_388.docx @ 2638557 @ @ 1
Module error (short-term)
• Short circuit or earth fault at the FI output
(motor cable or motor)
• Optional braking resistor, defect/check
• Optional motor choke, defect/check
Further notes
• More causes of error:
– Wrong size of breaking resistor
– Motor cable too long
– Cable resistance too high or voltage at Safe Pulse
Block too low
• Do not disconnect P537!
• The error may significantly reduce the service life of
the device or even destroy it.
Pos: 29 5 /Anlei tung en/El ektr onik/FU und Star ter/6 . Meld ungen zum Betr iebs zus ta nd/S törm el dung en (Auf list ung )/F ehl er E 008 [SK 500 P] @ 3 2\mod_1554280099547_388.docx @ 2525690 @ @ 1
(maximum EEPROM value
exceeded)
• Software version of the stored data set not compatible
with the software version of the FI.
NOTE: Faulty parameters are automatically reloaded
(factory setting).
• EMC interferences (see also E020)
(ControlBox)
• Check ControlBox for correct position
• ControlBox EEPROM defective (P550 = 1)
(Database version incorrect)
The configuration of the frequency inverter was not correctly
identified.
• Switch mains voltage off and on again.