82 BU 0600 en-2319
P106 Ramp smoothing S P
Setting range 0 … 100 %
Factory setting
{ 0 }
Description
This parameter enables smoothing of the acceleration and deceleration ramps. This is
necessary for applications where gentle, but dynamic speed change is important.
Ramp smoothing is carried out for every setpoint change.
The value to be set is based on the set acceleration and deceleration time, however
values <10 % have no effect.
The following then applies for the entire acceleration or deceleration time, including
ramp smoothing:
t
ges ACCELERATION TIME
= t
P102
+ t
P102
·
P106[%]
100%
t
ges BRAKING TIME
= t
P103
+ t
P103
·
P106[%]
100%
P102
P103
Output
frequency
Setpoint
frequency
Time
each
10 100 % of P102
each
10 100 % of P103