5 Parameter
BU 0600 en-2319 89
86 0.12 kW 115 V 96 1.10 kW 230 V 90T1/4 106 2.20 kW 400 V 90T1/4
87 0.18 kW 115 V 97 1.10 kW 230 V 80T1/4 107 3.00 kW 230 V 100T5/4
88
0.25 kW 115 V
98
1.10 kW 400 V 80T1/4
108
3.00 kW 230 V 100T2/4
89 0.37 kW 115 V 99 1.50 kW 230 V 90T3/4 109 3.00 kW 400 V 100T2/4
90 0.55 kW 115 V 100 1.50 kW 230 V 90T1/4 110 3.00 kW 400 V 90T3/4
91 0.75 kW 115 V 101 1.50 kW 400 V 90T1/4 111 4.00 kW 230 V 100T5/4
92
1.1 kW 115 V
102
1.50 kW 400 V 80T1/4
112
4.00 kW 400 V 100T5/4
93 4.0 PS 230 V 103 2.20 kW 230 V 100T2/4 113 4.00 kW 400 V 100T2/4
94 4.0 PS 460 V 104 2.20 kW 230 V 90T3/4 114 5.50 kW 400 V 100T5/4
95 0.75 kW 230 V 80T1/4 105 2.20 kW 400 V 90T3/4
P201 Nominal motor frequency S P
Setting range
10.0 … 399.9 Hz
Factory setting
{See Note}
Description The motor frequency determines the V/f break point at which the FI supplies the
nominal voltage P204 at the output.
Note
The default setting depends on the nominal power of the FI and the setting in P200.
P202 Nominal motor speed S P
Setting range
100 … 24000 rpm
Factory setting {See Note}
Description
The nominal motor speed is important for correct calculation and control of the motor
slip and the speed display (P001 = 1).
Note The default setting depends on the FI nominal power and the setting in P200.
P203 Nominal motor current S P
Setting range
0.1 … 1000.0 A
Factory setting
{See Note}
Description The nominal motor current is a decisive parameter for current vector control.
Note
The default setting depends on the nominal power of the FI and the setting in P200.
P204 Nominal motor voltage S P
Setting range
100 … 800 V
Factory setting {See Note}
Description
The nominal motor voltage matches the mains voltage to the motor voltage. In
combination with the nominal frequency, the voltage/frequency characteristic curve is
produced.
Note
The default setting depends on the FI nominal power and the setting in P200.