7 Additional information
BU 0630 en-2020 55
Pos: 34 0 /Anlei tung en/El ektr onik/S afety /8. Zus atzin form ationen /7. Si cherh eitsei nst ufunge n/ISO 13849- 1:2015_01 [SK 500P] @ 44\mod_1594804327625_388.docx @ 2646261 @ 3 @ 1
7.2.4 ISO 13849-1:2015
(German version EN ISO 13849-1:2016)
The shut-down method Safe Pulse Block for implementation of the STO safety function meets the
requirements of Performance Level e and category 4.
The Safety Digital Input for triggering motor braking for the SS1-t function meets the requirements of
Performance Level d and category 2.
Pos: 34 5 /Anlei tung en/El ektr onik/S afety /8. Zus atzin form ationen /7. Si cherh eitsei nst ufunge n/ISO 13849- 1:20 15_ 07 ( INFOR M ATI ON- B ew ertu ng der Si c herhei ts funk tio n) @ 44\m od_1594211871618_388.docx @ 2643864 @ @ 1
Evaluation of safety function
The values stated in the technical data only refer to the stated inputs or shut-down methods.
The components which are additionally required for the implementation of a safety function, such as
protective switching device, emergency stop button, etc. must also be taken into account for the
evaluation of the safety function. The resulting safety-relevant data can be significantly influenced by
these components.
Pos: 34 7 /Anlei tung en/El ektr onik/S afety /10. Te chnisc he Da ten/T echnisc he Dat en_ 01 @ 15\mod_1485524804221_388.docx @ 2317054 @ 1 @ 1