5 Parameter
BU 0600 en-2319 137
5.1.6 Additional parameters
P500 Language S P
Description Selection of the display language
Value Meaning Value Meaning Value Meaning
0 = German 1 = English 2 = French
3 = Spanish 4 = Swedish 5 = Netherlands
P501 Inverter name
(char)
Factory setting { 0 }
Free input of a designation (name) for the device (max. 20 characters). With this, the
frequency inverter can be uniquely identified for setting with NORDCON software or
within a network.
P502 Master function value S P
Arrays [-01] = Master value 1 [-02] = Master value 2 [-02] = Master value 3
Description Selection of master values of a Master for output to a bus system (see P503). These
master values are assigned to the slave via P546.
For details regarding the processing of setpoints and actual values, please refer to
Section 8.7.
Setting values
Value Meaning Value Meaning Value Meaning
Reserved POSICON
Actual frequency without slip
master value
01 = Actual frequency 11 =
02 = Actual speed 12 = BusIO Out Bits0-7 22 = Speed encoder
03 = Current 13 =
Reserved POSICON
23 = Actual frequency with slip
Master value actual frequency
with slip
06 =
Reserved POSICON
17 =
Value analogue input
1
… …
07 = 18 =
Value analogue input
2
57 = Actual value 5 PLC
08 = Setpoint frequency 19 =
Setpoint frequency
master value
58 = Clock input 1
09 = Error number 20 =
Setpoint frequency
after master value
ramp