EasyManua.ls Logo

Nord Drivesystems SK 530P - Table 10: Input Choke Data for SK CI1

Nord Drivesystems SK 530P
220 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NORDAC PRO (SK 500P)Users Manual for Frequency Inverters
32 BU 0600 en-2319
Type SK CI1-
chokes are specified for a
maximum supply voltage of 230 V or 480 V at
50/60 Hz.
All chokes have a protection class
corresponding to IP00. The choke used must
therefore be installed in a control cabinet.
Inverter ID
SK 5xxP
Input choke 3 x 380480 V
L1 B1 D
Detail: Fastening
Connection
Weight
Type
Continuous
current [A]
Inductance
[mH]
L2 B2
Assembly
0.55 ... 2.2 kW
SK CI1-480/6-C
Material No.:
276993006
6 3 x 4.88 96 60 117 71 45 M4 4 0.6
3.0 ... 4.0 kW
SK CI1-480/11-C
Material No.:
276993011
11 3 x 2.93 120 85 140 105 70 M4 4 2.1
5.5 kW
SK CI1-480/20-C
Material No.:
276993020
20 3 x 1.47 155 110 177 135 95 M5 10 5.7
[mm]
[mm
2
]
[kg]
Table 10: Input choke data for SK CI1-..., 3~ 480 V
D
L2
L1
B1
B2
L1
L2
L22
L12
L3
L32
Similar to illustration

Table of Contents

Other manuals for Nord Drivesystems SK 530P