4.2.2 Overview of control parameter settings
The following provides an overview of all parameters which are of importance, depending on the
selected operating mode. Among other things, a distinction is made between "relevant" and
"important", which provides an indication of the required precision of the particular parameter setting.
However, in principle, the more precisely the setting is made, the more exact the control, so that
higher values for dynamics and precision are possible for the operation of the drive unit. A detailed
description of these parameters can be found in Section 5 "Parameter".
"Ø" = Parameter has no significance "-" = Leave the parameter in the factory setting
"√" = Setting of the parameter is relevant "!" = Setting of the parameter is important
Group Parameter Operating mode
VFC open-loop CFC open-loop CFC closed-loop
ASMs PMSMs ASMs PMSMs ASMs PMSMs
Motor data
P201 … P209
P208 ! ! ! ! ! !
P210
1)
Ø
Ø
P211, P212
-
2)
-
-
-
-
-
P215, P216 -
1)
- - - - -
P217
Ø
Ø
P220
P240
-
-
-
P241 - - -
P243
-
-
-
P244
-
-
-
P246 - - -
P245, 247
-
Ø
Ø
Ø
Ø
Controller data
P300
P301
Ø
Ø
Ø
Ø
!
!
P310 … P320
Ø
Ø
P312, P313, P315, P316 Ø Ø - -
P330 … P333
-
-
-
P334 Ø Ø Ø Ø -
1)
=
For V/f characteristic curve: precise matching of the parameter is important.
2)
= For V/f characteristic curves: typical setting "0"