NORDAC SK 750E Manual
100 Technical design subject to change BU 0750 GB
Parameter
Setting value / Description / Note
Parameter
set
Available with option
P420
Digital input 1
BSC
STD
MLT
BUS
0 ... 48
[ 1 ]
Either no function is assigned at all in the factory or the enable right function (positive phase se-
quence).
A number of different functions are programmable. For detailed information see table below.
P421
Digital input 2
BSC
STD
MLT
0 ... 48
[ 2 ]
Either no function is assigned at all in the factory or the enable left function (negative phase se-
quence).
A number of different functions are programmable. For detailed information see table below.
P422
Digital input 3
BSC
STD
MLT
0 ... 48
[ 8 ]
In the factory the Switch parameter set function is assigned to this input.
A number of different functions are programmable. For detailed information see table below.
P423
Digital input 4
STD
MLT
0 ... 48
[ 4 ]
In the factory the Fixed frequency 1 function is assigned to this input.
A number of different functions are programmable. For detailed information see table below.
P424
Digital input 5
MLT
0 ... 25
[ 0 ]
In the factory no function is assigned to this input.
A number of different functions are programmable. For detailed information see table below.
P425
Digital input 6
MLT
0 ... 25
[ 0 ]
In the factory no function is assigned to this input.
A n umber of different functions are programmable. For detailed information see table below.