NORDAC SK 750E Manual
106 Technical design subject to change BU 0750 GB
Setting value / Description / Notes
14 = ... 29 not assigned for the time being
30 = Bus IO In Bit 0 / Bus In Bit 0 *
31 = Bus IO In Bit 1 / Bus In Bit 1 *
32 = Bus IO In Bit 2 / Bus In Bit 2 *
33 = Bus IO In Bit 3 / Bus In Bit 3 *
34 = Bus IO In Bit 4 / Bus In Bit 4 *
35 = Bus IO In Bit 5 / Bus In Bit 5 *
36 = Bus IO In Bit 6 / Bus In Bit 6 *
37 = Bus IO In Bit 7 / Bus In Bit 7 *
38 = Value Bus Setpoint *
*) P546...P548 = 17 bzw. 19
Adjustment of the limit values of the relay functions. Negative setting values will result in the function
being put out in a negated version.
Current limit = x [%] P203 >Rated motor current<
Torque current limit = x [%] P203 P206 (calculated nominal motor torque)
Frequency limit = x [%] P201 >nominal motor frequency<
Values in the range +/-20% are internally limited to 20% nominal.
The difference which is provided between operate point and release point to avoid oscillation of the
output signal.
Control terminals 3 / 4: The functions are identical with those described in P434.
The functions are identical with those described in P435.
The functions are identical with those described in P436.
The function of this parameter is identical to that of parameter P417 >Offset analogue output 1<, while
the setting will obviously be effective for analogue output 2.
The scope of functions is identical with that of analogue input 1. Read the precise description in pa-
rameter P418 >Function analogue output 1<.
The functions are identical with those described in P419.
For more details see the bus
manuals