NORDAC Control and Parameter Boxes
36 Subject to technical alterations BU 0040 GB-1611
2.3.1.4 Options
Parameter Setting value / Description / Note
P1301 Language
Value range:
see right hand column
[ … ]
Selection of languages for operation of the ParameterBox
Available languages: German English Polish Finnish
5
Dutch French Italian
4
Czech
5
Spanish Swedish Danish
5
Russian
5
P1302 Operating mode
Value range:
see right hand column
[Online]
Selection of the operating mode for the ParameterBox
Offline:
The ParameterBox is operated autonomously. No PC or frequency inverter is connected. The
storage objects of the ParameterBox can be parameterised and administrated.
Online:
One or more inverters are located at the interface of the ParameterBox. The frequency inverter
can be parameterised and controlled. When changing to the “ONLINE” operating mode, a bus
scan is started automatically.
PC slave:
A PC is located at the interface of the ParameterBox. The ParameterBox can be addressed as
a slave by the NORD CON software. The storage objects log on as separate frequency
inverters
S1  USS address 1
S2  USS address 2
S3  USS address 3
S4  USS address 4
S5  USS address 5
Note: If no storage object is saved, no object can be found by NORD CON.
P1303 Automatic bus scan
On, Off
[On]
Setting the switch-on characteristics.
Off
No bus scan is carried out, the frequency inverters connected before the switch-off are
located after switching on.
If the connection configuration has been changed (e.g. a different inverter has been
connected), error 223 is generated.
On
A bus scan is automatically implemented when the ParameterBox is switched on.
P1304 Contrast
0 ... 100 %
[ 50 ]
Contrast setting of the ParameterBox display
P1305 Set password
0 ... 9999
[ 0 ]
The user can set up a password in this parameter.
If a value other than 0 has been entered in this parameter, then the settings of the ParameterBox
or the parameters of the connected frequency inverter cannot be altered.
4
firmware version V4.3 or higher, (available from about the 3th quarter of 2011)