2 Parameter Boxes – System parameters
BU 0040 GB-1611 Subject to technical alterations 39
Display
Error number
Fault
Text in the ParameterBox
Cause
Remedy
Warnings
240 Overwrite data?
Yes No
241 Delete data?
Yes No
242 Different SW version?
Next Cancel
243 Different series?
Next Cancel
242 Delete all data?
Yes No
These warnings indicate that there is a possibly significant change which
needs additional confirmation.
Once the next procedure has been selected, it must be confirmed with the
"ENTER" key.
Inverter control error
250 This function is not enabled
The function requested is not enabled at the frequency inverter parameter
interface.
Change the value of the parameter >Interface< of the connected
inverter to the required function.
More detailed information can be obtained from the operating
instructions for the frequency inverter.
251 Control command was not successful
The control command cannot be implemented by the frequency inverter, as
a higher priority function, e.g. Quick stop or an OFF signal to the control
terminals of the frequency inverter is present.
252 Control is not possible offline
Call up of a control function in Offline mode.
Change the operating mode of the ParameterBox in the
parameter >Operating Mode< P1302 to Online and repeat the
action.
253 Error acknowledgement not successful
The acknowledgement of an error at the frequency inverter was not
successful, the error message remains in effect.
Error message from inverter
Inverter error
number
Inverter error text
A fault has occurred in the inverter with the number displayed. The inverter
error number and text are displayed.
2.4 Technical data
Name SK PAR-2H SK PAR-2E SK PAR-3H SK PAR-3E SK CSX-3H SK CSX-3E
Control voltage 4.5V
DC
… 30V
DC
Power consumption approx. 1.3 W approx. 1.3 W approx. 1.3 W approx. 1.3 W approx. 1.0 W approx. 1.0 W
Display Plain text display 4-digit, 7-segment display
Interfaces RS485 RS485 RS485 and
RS232
RS485 RS485 RS485
Ambient temperature 0°C … 40°C
Protection class IP54
1)
IP54
2)
IP54
3)
IP54
2)
IP54
3)
IP54
2)
Dimensions (L x W x D)
(90 x 145 x 27)
mm
(100 x 162 x
38) mm
(117 x 73 x 24)
mm
(128 x 83 x 32)
mm
(117 x 73 x 24)
mm
(128 x 83 x 32)
mm
Weight approx. 0.7 kg 0.5 kg 0.2 kg 0.6 kg 0.2 kg 0.6 kg
Connection cable length approx. 3m approx. 2m approx. 2m
1)
with plug inserted
2)
on the front side
3)
on plug socket IP20