NORDAC Control and Parameter Boxes
34 Subject to technical alterations BU 0040 GB-1611
Parameter Setting value / Description / Note
P1005 Standardisation factor
-327,67 … +327,67
[1.00]
The first value on the display list is scaled with the standardisation factor. Should this
standardisation factor deviate from 1.00, the unit of the scaled value is no longer displayed.
1
Display
>ENTER< / >OK<
ONLINE
I1 P1 Ready
P1004
2
Values for display
Actual frequency
ONLINE
I1 P1 Ready
P1004
2
Values for display
- Value adopted -
ONLINE
I1 P1 Ready
Possible actual values
for the display:
ControlBox*
Actual bus value abnormal
ZK voltage
Desired frequency
Torque current
Speed
Current
Voltage
Actual frequency
Value keys
Value +
Value -
OK
Press selection
keys simultaneously
+
530E 370W/230V
1
Fi/Hz U/V I/A
45.0 360 3.4
ONLINE
I1 P1 R RUNNING
P1001
P1002
P1003
P1005