6 Operating status messages
BU 0505 EN-3021 165
SimpleBox / ControlBox - display
The SimpleBox / ControlBox displays an error with its number and the prefix "E". In addition, the
current fault can be displayed in array element [-01] of parameter (P700). The last error messages are
stored in parameter P701. Further information on inverter status at the time that the error occurs can
be found in parameters P702 to P706 / P799.
If the cause of the error is no longer present, the error display in the SimpleBox / ControlBox flashes
and the error can be acknowledged with the Enter key.
In contrast, warning messages are prefixed with "C" ("Cxxx") and cannot be acknowledged. They
disappear automatically when the reason for them is no longer present or the frequency inverter has
switched to the "Error" state. Display of the message is suppressed if the warning appears during
parameterisation.
The present warning message can be displayed in detail at any time in array element [-02] of
parameter (P700).
The reason for an existing disabled switch on cannot be displayed with the SimpleBox / ControlBox.
Pos: 447 /Anleitungen/ Elektronik/F U und Starter/6. Meldungen zu m Betriebszustand/D arstellung der Meldungen - ParameterBox - Anzei ge @ 3\mod_1361801566355 _388.docx @ 59779 @ 5 @ 1
ParameterBox display
The ParameterBox displays the messages in plain text.
Pos: 448 /Anleitungen/ Elektronik/F U und Starter/6. Meldungen zu m Betriebszustand/Me ldungen @ 3\mod_1361803071 259_388.docx @ 59851 @ 2 @ 1
6.2 Messages
Pos: 449 /Anleitungen/ Elektronik/F U und Starter/6. Meldungen zu m Betriebszustand/Stör meldungen (Tabel lenüberschrift) @ 3\mod_1361803456862_388.d ocx @ 59874 @ 5 @ 1
Error messages
Display in the
SimpleBox / ControlBox
Fault
Text in the ParameterBox
Cause
Remedy
Group Details in P700
[-01] / P701
Pos: 450 /Anleitungen/ Elektronik/F U und Starter/6. Meldungen zu m Betriebszustand/Stör meldungen (Auflis tung)/Fehler E001 [ SK 180E/SK 2xxE/SK 5xxE] @ 2\mod_13 47452921592_388.doc x @ 46427 @ @ 1
E001
1.0 Overtemp. Inverter
"Inverter overtemperature"
(inverter heat sink)
Inverter temperature monitoring
measurements are outside of the permissible temperature
range, i.e. the error is triggered if the permissible lower limit
is undershot or the permissible upper temperature limit is
exceeded.
Depending on the cause: Reduce or increase the
ambient temperature
Check the FI fan / control cabinet ventilation
Check the FI for dirt
1.1 Overtemp. FI internal
"Internal FI overtemperature"
(interior of FI)
Pos: 451 /Anleitungen/ Elektronik/F U und Starter/6. Meldungen zu m Betriebszustand/Stör meldungen (Auflis tung)/Fehler E002 [SK 180E/SK 2xxE/SK 5xxE] @ 2\mod_1347453302 152_388.docx @ 46451 @ @ 1
E002
2.0 Overtemp. Motor PTC
"Overtemperature motor
thermistor "
Motor temperature sensor (PTC) has triggered
Reduce motor load
Increase motor speed
Use external motor fan
2.1 Overtemp. Motor I²t
"Motor overtemperature I²t"
Only if I
2
t motor (P535) is
programmed.
I
2
t motor has triggered (calculated overtemperature of
motor)
Reduce motor load
Increase motor speed
2.2 Overtemp. Brake r.ext
"Overtemperature of external
brake resistor "
Overtemperature via digital
input (P420 […])={13}
Temperature monitor (e.g. brake resistor) has activated
Digital input is Low
Check connection, temperature sensor