SK 54xEUsers Manual for Frequency Inverters
170 BU 0505 EN-3021
E020
E021
20.0 Reserved
System error in program execution, triggered by EMC
interference.
Observe wiring guidelines
Use additional external mains filter.
FI must be very well earthed.
20.1 Watchdog
20.2 Stack overflow
20.3 Stack underflow
20.4 Undefined opcode
20.5 Protected Instruct.
"Protected Instruction"
20.6 Illegal word access
20.7 Illegal Inst. Access
"Illegal instruction access"
20.8 Program memory error
"Program memory error"
(EEPROM error)
20.9 Dual-ported RAM
21.0 NMI error
(Not used by hardware)
21.1 PLL error
21.2 ADU error "Overrun"
21.3 PMI error "Access Error"
21.4 Userstack overflow
Pos: 471 /Anleitungen/ Elektronik/F U und Starter/6. Meldungen zu m Betriebszustand/Stör meldungen (Auflis tung)/Fehler E022 "r eservi ert" - PLC [SK 180E ... S K 5xxE] @ 2\mod_1361527702934_38 8.docx @ 59091 @ @ 1
E022
--- Reserved
Error message for PLC see supplementary instructions
BU 0550
Pos: 472 /Anleitungen/ Elektronik/F U und Starter/6. Meldungen zu m Betriebszustand/Stör meldungen (Auflis tung)/Fehler E023 "r eserviert" - PLC [SK 180E ... SK 5xxE] @ 2\mod_1361527808170_388.doc x @ 59116 @ @ 1
E023
--- Reserved
Error message for PLC see supplementary instructions
BU 0550
Pos: 473 /Anleitungen/ Elektronik/F U und Starter/6. Meldungen zu m Betriebszustand/Stör meldungen (Auflis tung)/Fehler E024 "r eservi ert" - PLC [SK 180E ... SK 5xxE] @ 6\mod_14 23644411761_388.doc x @ 201828 @ @ 1
E024
--- Reserved
Error message for PLC see supplementary instructions
BU 0550
Pos: 474 /Anleitun gen/Elektronik/F U und Starter/6. Meldungen z um Betriebszustand/ Störmeldungen (Auflis tung)/Fehler E025 " reserviert" [SK 54xE] @ 2\mod_1361 529602588_388.doc x @ 59166 @ @ 1
E025
--- Reserved
Error message for POSICON see supplementary
instructions
Pos: 475 /Anleitungen/ Elektronik/F U und Starter/6. Meldungen zu m Betriebszustand/W arnmeldungen (Tabelle nüberschrif t) @ 3\mod_1361803463080_388. docx @ 59898 @ 5 @ 1
Warning messages
Display in the
SimpleBox / ControlBox
Warning
Text in the ParameterBox
Cause
Remedy
Group Details in P700
[-02]
Pos: 476 /Anleitungen/ Elektronik/F U und Starter/6. Meldungen zu m Betriebszustand/Stör meldungen (Auflis tung)/Warnung C001 [S K 180E ... SK 5xxE ] @ 2 \mod_1347456220101_388. docx @ 46975 @ @ 1
C001
1.0 Overtemp. Inverter
"Inverter overtemperature"
(inverter heat sink)
Inverter temperature monitoring
Warning: permissible temperature limit reached.
Reduce ambient temperature
Check the FI fan / control cabinet ventilation
Check the FI for dirt
Pos: 477 /Anleitungen/ Elektronik/F U und Starter/6. Meldungen zu m Betriebszustand/Stör meldungen (Auflis tung)/Warnung C002 [S K 180E/SK 2xxE/SK 5xxE] @ 2\mod_13474562239 54_388.docx @ 47000 @ @ 1
C002
2.0 Overtemp. Motor PTC
"Overtemperature motor
thermistor "
Warning from motor temperature sensor (triggering
threshold reached)
Reduce motor load
Increase motor speed
Use external motor fan

Table of Contents