6 Operating status messages
BU 0505 EN-3021 171
2.1 Overtemp. Motor I²t
"Motor overtemperature I²t"
Only if I
2
t motor (P535) is
programmed.
Warning: I2t- motor monitoring (1.3 times the rated current
reached for the time period specified in (P535))
Reduce motor load
Increase motor speed
2.2 Overtemp. Brake r.ext
"Overtemperature of external
brake resistor "
Overtemperature via digital
input (P420 […])={13}
Warning: Temperature monitor (e.g. brake resistor) has
activated
Digital input is Low
Pos: 478 /Anleitungen/ Elektronik/F U und Starter/6. Meldungen zu m Betriebszustand/Stör meldungen (Auflis tung)/Warnung C003 [S K 180E ... SK 5xxE] @ 2\mod_1347457 006237_388.doc x @ 47199 @ @ 1
C003
3.0 Overcurrent, I
2
t limit
Warning: Inverter: I
2
t limit has triggered, e.g. > 1.3 x I
n
for
60s (please also note P504)
Continuous overload at FI output
3.1 Overcurrent, chopper I
2
t
Warning: I
2
t limit for the brake chopper has triggered, 1.3x
value attained for 60s (also note P554, if present, as well as
P555, P556, P557)
Avoid overload of brake resistance
3.5 Torque current limit
Warning: Torque current limit reached
Check (P112)
3.6 Current limit
Warning: Current limit reached
Check (P536)
Pos: 479 /Anleitungen/ Elektronik/F U und Starter/6. Meldungen zu m Betriebszustand/Stör meldungen (Auflis tung)/Warnung C004 [S K 180E ... SK 5xxE] @ 2\mod_1347457 006705_388.doc x @ 47224 @ @ 1
C004
4.1 Overcurrent measurement
"Overcurrent measurement"
Warning: pulse switch off is active
The limit for activation of pulse switch off (P537) has been
reached (only possible if P112 and P536 are switched off)
FI is overloaded
Drive sluggish, insufficiently sized
Ramps (P102/P103) too steep -> Increase ramp time
Check motor data (P201 … P209)
Switch off slip compensation (P212)
Pos: 480 /Anleitungen/ Elektronik/F U und Starter/6. Meldungen zu m Betriebszustand/Stör meldungen (Auflis tung)/Warnung C008 [S K 180E ... SK 5xxE] @ 2\mod_1347457 201563_388.doc x @ 47249 @ @ 1
C008
8.0 Parameter loss
Warning: One of the cyclically saved messages such
as operating hours or enabling time could not be
saved successfully.
The warning disappears as soon as saving can be
successfully performed.
Pos: 481 /Anleitungen/ Elektronik/F U und Starter/6. Meldungen zu m Betriebszustand/Stör meldungen (Aufli stung)/Warnung C012 [ SK 5xxE] @ 2\mod_1361539953 134_388.docx @ 59296 @ @ 1
C012
12.1 Motor Limit / Customer
"Motor switch-off limit"
Warning: 80 % of the drive switch-off limit (P534 [-01]) has
been exceeded.
Reduce load on motor
Set higher value in (P534 [-01]).
12.2 Generator limit
"Generator switch-off limit"
Warning: 80 % of the generator switch-off limit (P534 [-02])
has been reached.
Reduce load on motor
Set higher value in (P534 [-02]).
12.5 Load monitor
Warning due to overshooting or undershooting of
permissible load torques ((P525) … (P529)) for the time set
in (P528).
Adjust load.
Change limit values ((P525) ... (P527)).
Increase delay time (P528).
Pos: 482 /Anleitungen/ Elektronik/F U und Starter/6. Meldungen zu m Betriebszustand/Me ldungen Einschaltsper re (Tabellenübersc hrift) @ 3\mod_13618034 67385_388.doc x @ 59922 @ 5 @ 1