EasyManua.ls Logo

nord NORDAC PRO SK 511E Series - Electrical Data 230 V

nord NORDAC PRO SK 511E Series
218 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SK 54xEUsers Manual for Frequency Inverters
178 BU 0505 EN-3021
7.3.2 Electrical data 230 V
Note: Fields with 2 values (separated by a forward slash) should be read as follows:
The first value applies for a single phase mains connection
The second value applies for a three-phase mains connection
Frequency inverter type SK 5xxE…
-250-323- -370-323- -550-323- -750-323-
Size
1 1 1 1
Nominal motor power
(4-pole standard motor)
230 V
0.25 kW 0.37 kW 0.55 kW 0.75 kW
240 V
1
/
3
hp ½ hp ¾ hp 1 hp
Mains voltage
230 V
1 / 3 AC 200 … 240 V, ± 10 %, 47 … 63 Hz
Input current
rms
3.7 / 2.4 A 4.8 / 3.1 A 6.5 / 4.2 A 8.7 / 5.6 A
FLA
3.7 / 2.4 A 4.8 / 3.1 A 6.5 / 4.2 A 8.7 / 5.6 A
Output voltage
230 V
3 AC 0 - Mains voltage
Typical output
rms
1.7 A 2.2 A 3.0 A 4.0 A
FLA
1.7 A 2.2 A 2.9 A 3.9 A
Min. brake resistor Accessories
240 190 140 100
Pulse frequency
range
3 16 kHz
Factory setting
6 kHz
Ambient temperature S1
40 °C 40 °C. 40 °C. 40 °C.
S3 80 %, 10 min
50 °C. 50 °C. 50 °C. 50 °C.
S3 70 %, 10 min
50 °C. 50 °C. 50 °C. 50 °C.
Type of ventilation
Free convection
Weight Approx. [kg]
1.6
General fuses (AC) (recommended)
slow-blowing
6 / 6 A 6 / 6 A 10 / 6 A 10 / 6 A
Isc
1)
[A]
UL fuses (AC) permitted
Class
5 000
10 000
100 000
Fuse
J (600 V) x
4 / 2.5 A 5 / 3.2 A 7 / 4.5 A 9 / 6 A
CC, J, R, T, G, L (300 V)
x
6 / 6 A 6 / 6 A 10 / 10 A 25 / 10 A
Bussmann LPJ-
x
4SP / 2.5SP 5SP / 3.2SP 7SP / 4.5SP 9SP / 6SP
CB
(480 V)
x
5 / 5 A 5 / 5 A 10 / 10 A 10 / 10 A
1) Maximum permissible mains overload current

Table of Contents