8 Additional information
BU 0505 EN-3021 191
8.2 Process controller
The process controller is a PI controller which can be used to limit the controller output. In addition, the
output is scaled as a percentage of a master setpoint. This provides the option of controlling any
downstream drives with the master setpoint and readjusting using the PI controller.
Fig. 15: Process controller flow diagram
Pos: 499 /Anleitungen/ Elektronik/F U und Starter/9. Zusatzinf ormationen [BU 0500 / BU 0200] /Prozessregler/A nwendungsbeispiel Pr ozessregler [SK 1x0E, SK 2xxE, SK 5xxE] @ 0\mod_13 28186990203_388.d ocx @ 14190 @ 3 @ 1
8.2.1 Process controller application example
Master
setpoint
(P400=4)
or
Setpoint
P412 = 0.0-10.0V
Controlled drive via CR
Actual value
(P400=14)
or
Analog input 2
Compensating roller = CR (dancer roller)
Ramp PID controller P416
Pilot machine
P-Factor P413
I-Factor P414
Actual
via
PI controller
nominal
position
Min. limitation
P466
Lead
Analog input 1
(P400 = 16)
Start-up time P102
Setpoint ramp
Max. limitation