EasyManua.ls Logo

nord NORDAC PRO SK 511E Series - Table 38: EMC, Max. Shielded Motor Cable Length with Regard to Compliance with the Limit Value Classes; Table 39: Overview According to Product Standard en 61800-3

nord NORDAC PRO SK 511E Series
218 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 Additional information
BU 0505 EN-3021 195
Inverter type
Jumper position /
DIP: "EMC-Filter"
(chapter 2.9.2)
Conducted emissions
150 kHz - 30 MHz
Class C2 Class C1
SK 5xxE-250-323-A … SK 5xxE-401-323-A
3 – 2 20 m 5 m
3 – 3 5 m -
SK 5x5E-551-323-A … SK 5x5E-182-323-A 4 – 2 20 m -
SK 5xxE-550-340-A … SK 5xxE-751-340-A
3 – 2
20 m
5 m
3 – 3
5 m
-
SK 5xxE-550-340-A … SK 5xxE-751-340-A
+ suitable bottom-mounted combination filter
SK NHD-…
3 – 2 100 m 50 m
SK 5xxE-550-340-O … SK 5xxE-751-340-O
+ suitable bottom-mounted combination filter
SK NHD-…
3 – 2 100 m 25 m
SK 5x5E-112-340-A … SK 5x5E-372-340-A
4 – 2
20 m
-
SK 5x5E-112-340-A … SK 5x5E-372-340-A
+ suitable bottom -mounted SK LF2-…
4 – 2 100 m 50 m
SK 5x5E-112-340-O … SK 5x5E-372-340-O
+ suitable bottom -mounted SK LF2-…
4 – 2 100 m 25 m
SK 5x5E-452-340-A … SK 5x5E-163-340-A
DIP: ON
20 m
-
Table 38: EMC, max. shielded motor cable length with regard to compliance with the limit value classes
Pos: 501.7 /Anleitung en/Elektronik/F U und Starter/8. /9. Zusatzinformationen [BU 0500 / BU 0200]/EMV/_EMV des Ger ätes _ Grenzwertklassen @ 2\m od_1347443407776_3 88.docx @ 46088 @ @ 1
EMC overview of standards that are used in accordance with EN 61800-3
as checking and measuring procedures:
Interference emission
Cable-related emission
(interference voltage)
EN 55011
C2
C1 (BG 1-4)
Radiated emission
(interference field strength)
EN 55011
C2
-
Interference immunity EN 61000
-6-1, EN 61000-6-2
ESD, discharge of static electricity
EN 61000-4-2
6 kV (CD), 8 kV (AD)
EMF, high frequency electro-magnetic
fields
EN 61000-4-3 10 V/m; 80 1000 MHz
Burst on control cables
EN 61000-4-4
1 kV
Burst on mains and motor cables
EN 61000-4-4
2 kV
Surge (phase-phase / phase-ground)
EN 61000-4-5
1 kV / 2 kV
Cable-led interference due to high
frequency fields
EN 61000-4-6 10 V, 0.15 80 MHz
Voltage fluctuations and drops
EN 61000-2-1
+10 %, -15 %; 90 %
Voltage asymmetries and frequency
changes
EN 61000-2-4 3 %; 2 %
Table 39: Overview according to product standard EN 61800-3
Pos: 501.8 /Anleitung en/Elektronik/F U und Starter/8. /9. Zusatzinformationen [BU 0500 / BU 0200]/EMV/_EMV_Ver drahtungsempfehlun g (FU's) @ 5\mod_139695799 4490_388.docx @ 125877 @ @ 1

Table of Contents

Related product manuals