2 Assembly and installation
BU 0505 EN-3021 35
2.5 EMC Kit
For optimum EMC-compliant wiring, the optional EMC Kit must be used.
Fig. 2: EMC Kit SK EMC2-x
Frequency inverter type Size
EMC Kit Document Dimension "b"
SK 5xxE-250- … SK 5xxE-750- Size 1
SK EMC 2-1
Part No. 275999011
TI 275999011
42 mm
SK 5xxE-111- … SK 5xxE-221- Size 2
SK 5xxE-301- … SK 5xxE-401- Size 3
SK EMC 2-2
Part No. 275999021
TI 275999021
42 mm
SK 5xxE-551-340- … SK 5xxE-751- 340- Size 4
SK 5xxE-551-323- … SK 5xxE-751- 323-
SK 5xxE-112-340- … SK 5xxE-152- 340-
Size 5
SK EMC 2-3
Part No. 275999031
TI 275999031
52 mm
SK 5xxE-112-323-
SK 5xxE-182-340- … SK 5xxE-222- 340-
Size 6
SK EMC 2-4
Part No. 275999041
TI 275999041 57 mm
SK 5xxE-152-323- … SK 5xxE-182- 323-
SK 5xxE-302-340- … SK 5xxE-372- 340-
Size 7
SK EMC 2-5
Part No. 275999051
TI 275999051 57 mm
SK 5xxE-452-340- … SK 5xxE-902- 340- Size 8/9
Part No. 275999061
TI 275999061
100 mm
SK 5xxE-113-340- … SK 5xxE-163- 340- Size 10/11
Part No. 275999071
TI 275999071
82 mm
Table 5: EMC Kit SK EMC2-x
The EMC Kit cannot be combined with ...-CP (ColdPlate) devices. Any cable shielding must be earthed to a large
area of the mounting surface.
Alternatively, the EMC kit can also be used purely as a strain relief (e.g. for the connection cables of a bus
system) (observe the bending radii).
Pos: 45 /Anleitungen/ Elektronik/FU und St arter/2. Montage und Inst allation/Zubehör/ Bremswiderstand/SK 500E2.6 Bremswiders tand (BW) [BU 0500] @ 0\mod_132 5862128510_388.doc x @ 5848 @ 2 @ 1