EasyManua.ls Logo

nord NORDAC PRO SK 511E Series - EMC Kit; Fig. 2: EMC Kit SK EMC2-X; Table 5: EMC Kit SK EMC2-X

nord NORDAC PRO SK 511E Series
218 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Assembly and installation
BU 0505 EN-3021 35
2.5 EMC Kit
For optimum EMC-compliant wiring, the optional EMC Kit must be used.
b
Similar to illustration
Fig. 2: EMC Kit SK EMC2-x
Frequency inverter type Size
EMC Kit Document Dimension "b"
SK 5xxE-250- … SK 5xxE-750- Size 1
SK EMC 2-1
Part No. 275999011
TI 275999011
42 mm
SK 5xxE-111- … SK 5xxE-221- Size 2
SK 5xxE-301- … SK 5xxE-401- Size 3
SK EMC 2-2
Part No. 275999021
TI 275999021
42 mm
SK 5xxE-551-340- … SK 5xxE-751- 340- Size 4
SK 5xxE-551-323- … SK 5xxE-751- 323-
SK 5xxE-112-340- … SK 5xxE-152- 340-
Size 5
SK EMC 2-3
Part No. 275999031
TI 275999031
52 mm
SK 5xxE-112-323-
SK 5xxE-182-340- … SK 5xxE-222- 340-
Size 6
SK EMC 2-4
Part No. 275999041
TI 275999041 57 mm
SK 5xxE-152-323- … SK 5xxE-182- 323-
SK 5xxE-302-340- … SK 5xxE-372- 340-
Size 7
SK EMC 2-5
Part No. 275999051
TI 275999051 57 mm
SK 5xxE-452-340- … SK 5xxE-902- 340- Size 8/9
SK EMC 2-6
Part No. 275999061
TI 275999061
100 mm
SK 5xxE-113-340- … SK 5xxE-163- 340- Size 10/11
SK EMC 2-7
Part No. 275999071
TI 275999071
82 mm
Table 5: EMC Kit SK EMC2-x
Information
The EMC Kit cannot be combined with ...-CP (ColdPlate) devices. Any cable shielding must be earthed to a large
area of the mounting surface.
Alternatively, the EMC kit can also be used purely as a strain relief (e.g. for the connection cables of a bus
system) (observe the bending radii).
Pos: 45 /Anleitungen/ Elektronik/FU und St arter/2. Montage und Inst allation/Zubehör/ Bremswiderstand/SK 500E2.6 Bremswiders tand (BW) [BU 0500] @ 0\mod_132 5862128510_388.doc x @ 5848 @ 2 @ 1

Table of Contents

Related product manuals