2 Assembly and installation
BU 0505 EN-3021 75
Function Signal designation Signal voltage
ss
Cosine signal Cos max. 5V U
ss
Table 25: Signal details for SIN/COS encoders
Pos: 104 /Anleitungen/ Elektronik/F U und Starter/2. Montage und Ins tallation/Elektr ischer Anschluss/ Drehgeber/Farb- und Kontaktbelegung f ür Drehgeber- Hiperfac e Geber [SK 54xE] @ 1\mod_13312161236 68_388.docx @ 17902 @ 5 @ 1
Hiperface encoder
Hiperface is a mixture of incremental encoder and absolute encoder and combines the advantages of
both encoder types. The absolute value is initially only formed when the device is switched on and is
communicated by the RS485 specification bus parameter interface to the external counter in the
controller, which then continues counting incrementally from this absolute value using the analog
sine/cosine signal. During operation the counted position is continuously compared with the measured
absolute position of the encoder.
Hiperface encoders are suitable for positioning in combination with servo mode.
The requirements for the analog signal are shown in the following table. It must be noted that the
tolerances in the voltages affect the precision of the determined position.
The supply voltage for the encoder is 7-12V. An external source or the internal 12V voltage can be
used as the voltage supply.
Function Signal designation Signal voltage
Sine reference voltage Sin Ref 2.5V U
m
Cosine reference voltage Cos Ref 2.5V U
m
Sine signal Sin 1V U
ss
Cosine signal Cos 1V U
ss
Table 26: Signal details for Hiperface encoders
ss