120 Subject to technical alterations BU 0500 GB
Parameter Set value / Description / Note Device Supervisor
Parameter
set
P748 ... - 01
... - 03
Status CANopen
SK 520E
and above
S
[01] = CANbus/CANopen Status [02] = reserved [03] = reserved
Bit 0 = 24V Bus supply voltage
Bit 1 = CANbus in status “Bus Warning”
Bit 2 = CANbus in status “Bus Off”
Bit 3 ... 5 = free
Bit 6 = Protocol of the CAN module is
0 = CAN or 1 = CANopen
Bit 7 = free
Bit 8 = „Bootsup Message“ sent
Bit 9 = CANopen NMT State
Bit 10 = CANopen NMT State
Bit 11 = free
Bit 12 ... 14 = reserved
Bit 15 = free
CANopen NMT State Bit 10 Bit 9
Stopped =
Pre-Operational =
Operational =
0
1
1
1
0
1
0000 ... FFFF (hex)
P750 Overcurrent statistic
S
0 ... 9999 Number of overcurrent messages during the operating period P714.
P751 Over voltage statistic
S
0 ... 9999 Number of overvoltage messages during the operating period P714.
P752 Mains supply faults
S
0 ... 9999 Number of mains faults during the operating period P714.
P753 Overheating statistics
S
0 ... 9999 Number of overtemperature faults during the operating period P714.
P754 Parameter loss statistic
S
0 ... 9999 Number of parameters lost during the operating period P714.
P755 System faults statistic
S
0 ... 9999 Number of system faults during the operating period P714.
P756 Time out statistics
S
0 ... 9999 Number of Time out errors during the operating period P714.
P757 Customer faults statistic
S
0 ... 9999 Number of Customer Watchdog faults during the operating period P714.
P799 ... - 01
...
... - 05
Operating hours, latest fault 1…5
0.1 ... ___ h This parameter shows the operating hours counter status (P714) at the moment of the previous
fault. Array 01…05 corresponds to the lastest fault 1…5.