8.1 Setpoint processing in the SK 5xxE
Analog input 1
Analog input 2
Bus setpoint 1,2,3
Main
setpoint sources
Analog input 1
Analog input 2
Bus setpoint 3
Bus setpoint 2
P411
P410
Scaling
+
Fixed frequency 1-5
P429-P433
P509
P400
P405
P549
P547
Inter f ac e
Auxiliary
setpoint sources
P546-P548
ControlBox /
PotentiometerBox
PotentiometerBox
P548
Auxiliary setpoint standardisation
Frequency main setpoint
P400-P404
Scaling
P510
B u s se l e ct i o n
Jog frequency
(also with ControlBox)
P113
+
Funct. digital input:
P549
±1
Frequency addition /
Frequency subtraction
Direction of rotation
P405-P409
Scaling
P105
P104
Scaling
P400-P404
Scaling
P405-P409
Scaling
P549
Inc
P325

Table of Contents