2 Assembly and installation
BU 0500 GB Subject to technical alterations 19
2.4 EMC- Kit
For optimum EMC-compliant wiring, the optional EMC Kit must be used. This includes a screening angle and
two hammer clips.
The EMC Kit provides the possibility of attaching the screening of the motor cable to a large surface of the
frequency inverter (interference source). If necessary a screened brake resistor cable can be attached with the
two hammer clips.
The screening angle is attached to the two housing screws on the lower edge (below the U-V-W terminals).
The motor cable screening is earthed to a large area of the screening angle by means of the hammer clip.
Device type Size
EMC- Kit
SK 5xxE-250- … SK 5xxE-750- S1
SK 5xxE-111- … SK 5xxE-221- S2
SK EMC 2-1
Mat. No. 275999011
SK 5xxE-301- … SK 5xxE-401- S3
SK 5xxE-551- … SK 5xxE-751- S4
SK EMC 2-2
Mat. No. 275999021
Note: The EMC Kit cannot be combined with ...-CP (ColdPlate) devices. Any cable screening must be
earthed to a large area of the mounting surface.