support the weight of the charger and cable in
safe and stable way. For example, hang the
charger on a hook, via the hang hole on the back
of the product.
15. If you have the charger or cable on the
ground, they can be easily be damaged, keep
them off the ground and protected from fall
damage.
16. This product may cause a tripping hazard.
17. Regular wall outlets and engine preheater
outlets (Schuko type), are not made for electric
vehicle charging and cannot handle recurring high
load over long periods. Therefor limit the charge
to 10A. This limitation does not include industrial
contacts (IEC/EN 60309)
18. Old or erroneous contacts or cable line
branches in the building can cause overheating at
high loads, which in turn can be a fire risk.
Because of this risk, let an authorized electrical
installation company check the electrical
installation.
Use locations
Typical use locations for this product would be
sheltered locations or areas with roofs, such as a
garage or a parking lot with a roof.
Compatibility
Charger EV-1125 is for all electrical vehicles with
Type 1 contacts.
Charger EV-1225 is for all electrical vehicles with
Type 2 contacts.
Do not use them with other types.
Use
1. Connect to a power supply. (To an earthed
contact)
2. Use the button to switch between 10A/16A.
3. Connect to the electrical vehicle’s contact.
The charger automatically detects the connection
status, handshaking protocol and starts charging.
LED status
The LED marked with the word “Power” can be lit
green or off.
The LED marked with the “10A”/ “16A” can be lit
green for 10A, lit blue for 16A or off.
The LED marked with the word “Fault can be lit
red or off.
Combinations of the LEDs status has different
meanings:
Connected to power: “Power” is on, “10A”/ 16A”
and “Fault” is lit for 0.5 seconds.
Ready for charging: “Power” is on, “10A”/ “16A” is
on, “Fault” is off.
Normal charging: “Power” is on, “10A”/ “16A
flashes every 1 second, “Fault” is off.
Charging fault: “Power” is on, “10A”/ “16A” is off,
“Fault” is on.
Charging completed: “Power” is on, “10A”/ “16A”
is off, “Fault” is off.
Fault status
The LED marked with “Fault” will flash differently
depending on fault, activated protection:
Flashes 1 time, communication failure.
Flashes 2 times, under-voltage protection.
Flashes 3 times, over-voltage protection.
Flashes 4 times, ungrounded protection.
Flashes 5 times, over-current protection.
Flashes 6 times, short-circuit protection.
Flashes 7 times, current leakage protection.
Flashes 8 times, over-temperature protection.
Cleaning
Disconnect from power and use a dry cloth for
cleaning this device.
Support
More product information can be found at
www.deltaco.eu.
Contact us by e-mail: help@deltaco.eu.
FIN
Kiitos, kun valitsit Deltaco-tuotteen!
Turvallisuusohjeet
1. Noudata käyttöohjeita, kun käsittelet tuotetta.
Ohjeiden noudattamatta jättäminen saattaa johtaa
henkilö- tai omaisuusvahinkoon.
2. Tutustu ajoneuvon omiin ohjeisiin, ennen kuin
alat ladata sitä.
3. Tarkista säännöllisesti, ettei laturissa ole
näkyviä vaurioita. Viallisen laturin käyttäminen
saattaa aiheuttaa sähköiskun vaaran.