3-6
lnstallation
Connecting
the
RTD
Sensor
@ontd.)
WARNING: Electricalshock hazard
exists if hose
ground
wire
is not
secured tightly to the
gun
body.
o
A
Fig.3-8 Connecting
the Ground
Wire
Fig.3-9 Connecting the Heater
5. Secure the
ground
wire
to the
RTD
side of the
pivot
sleeve. Do not
overtighten.
Connecting the Heater
6. On the heater side of
the
pivot
sleeve,
loosen
the two screws on the
heater terminal block
as shown in
Figure
3-9. lnsert wires L and J,
extending from
the
hose, into
the terminal block.
7. Tighten
the two terminal-block screws to 0.42 N.m
(3.7
lbf-in.),
taking
care not
to overtighten.
GND
B
H
oo
oo
oo
4209074
L
oo
OS
os
4203081
A3EN{'4-[AD-01EXl-1
42-72