Troubleshooting
8-4
Part 1120130
E 2011 Nordson Corporation
Touch Screen Alerts and Faults
The Nordson AltaBlue Touch Adhesive melter diagnoses many alert and
fault conditions that may occur during operation. An “alert” condition is a
situation in which a potential problem may be occurring with the melter,
pump, applicator or hose. The melter will operate under an “alert” condition
unless the problem goes unresolved, at which point the melter will go into a
“fault” condition, during which the melter will shut down until the problem is
resolved.
Refer to the appropriate table for more information.
About Touch Screen Messages
Pump and Zone Alerts/Faults
Table 8-1 Pump and Zone Alerts/Faults
Screen Message Affect on Melter Cause Corrective Action(s)
Internal or External
Temperature for
[ZoneName] has
dropped below
defined setpoint
threshold
Alert condition - an
issue has been
detected. The
melter continues to
operate normally.
Fault condition - if
the issue is not
resolved within 2
minutes of the alert
message, the
master pump and
heaters are switched
off. Melter stops
functioning
The actual temperature of the
component has dropped below
the set temperature limit
Check for conditions that may
cause a drop in ambient
temperature or replace the
component.
Internal or External
Temperature for
[ZoneName] has
risen above defined
setpoint threshold
The actual temperature of the
component has risen above the
set temperature limit
Check for conditions that may
cause an increase in ambient
temperature or replace the
component.
Internal or External
Short RTD on
[ZoneName]
The RTD for the component
indicated has failed or the
component was disconnected
from the melter.
Check the connections, or
replace the RTD
Internal or External
Open RTD on
[ZoneName]
Issue with a pump
The melter may not
continue to work.
Refer to “Troubleshooting Pumps“ later in this section for more
information